To calculate mini tank air usage: Start by measuring your breathing rate (Breaths Per Minute - BPM). At the surface wearing all dive gear,
breathe normally from the tank for 1 minute and count your breaths. This is your Surface Air Consumption (SAC) baseline.
Find your tank's usable capacity. For a common 3L mini tank, the working pressure is often 300 bar. Usable air is (Tank Volume) x (Start Pressure - Reserve Pressure). Example: 3L x (300 bar - 50 bar reserve) = 750 litres.
Your actual air use underwater increases with depth. Multiply your SAC rate (in litres/minute) by (Depth in meters / 10) + 1. At 10 meters depth, air use doubles: SAC x 2.
Total Bottom Time = (Total Usable Litres) / (SAC x Depth Factor). If your SAC is 15 L/min and you're at 10m (factor=2): 750 Litres / (15 x 2) = 750 / 30 = 25 minutes.
Crucially: Monitor your pressure gauge at least every 5 minutes during the dive and ascend with at least 50 bar remaining.
Step 1: Check Your Tank Capacity
Every aluminum mini tank manufactured post-2005 adheres to ISO 13769 standards, displaying volume within ±0.2L tolerance on the shoulder engraving. Locate the "V" symbol followed by a numeric value (e.g., V = 3.0 for a 3-liter tank), stamped alongside the working pressure rating—typically 200 bar (2,900 PSI) for recreational tanks, though high-pressure 300-bar (4,350 PSI) models exist. Physical verification is non-negotiable: A Faber FX series 2.9L tank misread as 3.0L causes a 3.4% air volume error, escalating to a 17-minute bottom time miscalculation at 20m depth. Multiply volume by pressure to derive total capacity: A V=2.0L tank at 200 bar holds 400 liters (2.0 × 200), but usable air requires subtracting 50 bar reserve pressure, leaving only 350 liters (87.5% of total) for actual consumption. Temperature-induced compression shrinks capacity: For every 5°C (9°F) drop below 25°C (77°F), internal pressure decreases by approximately 7 bar, reducing a 200-bar fill at 15°C to 186 bar—a 7% air loss before immersion. Tank aging also degrades accuracy: After 15 years of service, aluminum tanks experience ~0.5% permanent volume expansion, requiring recalibration every 5 hydrostatic tests (mandatory every 5 years). Common misidentifications include confusing DOT 3AA2015 (standard 7.25" diameter) with compact DOT SP2015 tanks (6.9" diameter), where a 0.35" size difference masks a 12% volume discrepancy.
Reference Data Table:
Parameter | Steel Tanks | Aluminum Tanks |
---|---|---|
Common Volume | 1.5L–2.0L | 2.0L–3.0L |
Working Pressure | 232 bar | 200 bar |
Residual Pressure Reserve | 50 bar | 50 bar |
Thermal Pressure Loss (per 5°C↓) | 3.1 bar | 7 bar |
Expansion Rate (15+ years) | <0.1% | 0.5% |
Hydro Test Interval | 60 months | 60 months |
Critical Takeaways:
Always use engraved markings, not paint labels: Printed text fades after 25 dives in saltwater.
Calculate usable air as (Volume × [Start Pressure – 50 bar]).
For a 3.0L tank starting at 200 bar: 3.0 × (200 – 50) = 450 liters available.
Field-check capacity with a pressure gauge: A full 3.0L/200 bar tank shows ~100 PSI drop per 15 breath cycles at the surface.
Cold-water correction: If filling at 15°C and diving at 5°C, multiply capacity by 0.93 (7% loss).
Failure Example:
Assuming a 2.7L tank is 3.0L and diving to 18m:
Actual usable air: 2.7L × (200 – 50) = 405 liters
Estimated air (wrong): 3.0L × 150 = 450 liters
Overestimate: 45 liters (11% surplus)
At SAC rate 20 L/min × 2.8 depth factor: 45L ÷ 56 L/min = 0.8 minutes early air exhaustion.
Step 2: Time Breaths at the Surface with Gear (Count Breaths per Minute)
Sit neck-deep in 25–30°C (77–86°F) water wearing your exact dive kit—wetsuit, BC, regulator, weights—and remain motionless for 180 seconds; this eliminates exertion bias, as studies show heart rate drops to resting baseline (±2 BPM) after 90–120 seconds immersion. Initiate a stopwatch at the start of inhalation, counting every full breath cycle (inhale + exhale) for 60.00 seconds; experienced divers average 8–12 BPM at rest, while novices range 14–22 BPM, with cold water (<18°C/64°F) spiking rates by 15–25% due to thermal shock. Record three trials: If results are 12, 11, and 13 BPM, calculate the mean (12.0), never rounding, as a 0.5 BPM error at 20m depth causes 18% air miscalculation.
Gear drastically alters breathing:
A 7mm neoprene wetsuit compresses the thoracic cavity, reducing lung capacity by 12% and forcing +2.4 BPM to maintain oxygen flow.
Poorly maintained regulators add 15–30% inhalation resistance; a second-stage needing 1.8 kg force to open (vs. standard 1.2 kg) increases BPM by 3–5.
A full 12kg weight belt restricts diaphragm movement, elevating BPM by 1.8–2.2 versus belt-free breathing.
Environmental corrections:
Water temperature: For each 1°C drop below 25°C, add 0.3 BPM to your measured rate (e.g., 20°C water = +1.5 BPM).
Surface current: Gentle 0.5-knot flow raises BPM by 4–6 due to finning compensation.
Anxiety: New divers show +8–12 BPM during first measurements, requiring 3+ practice sessions to normalize.
Quantifying air consumption:
Your Surface Air Consumption (SAC) rate is calculated as:
SAC (L/min) = (Tank Volume × Pressure Drop per Minute) ÷ Test Duration
Example for a 3.0L tank:
Start pressure: 200 bar
After 60 seconds at 12 BPM: End pressure 198.8 bar
Pressure drop = 1.2 bar
SAC = (3.0L × 1.2 bar) / 1 min = 3.6 L/min
Error minimization :
Use a digital pressure transducer (accuracy ±0.1 bar) for measurements.
Conduct tests at identical times of day—BPM fluctuates ±7% circadianly.
Novices: Add 25% safety margin to calculated SAC.
Pro tip: If SAC exceeds 20 L/min, service your regulator—sticky valves cause 50% excess consumption.
Critical Data Reference:
Factor | Impact on BPM | Air Use Consequence |
---|---|---|
Wetsuit Thickness | +1.5 BPM per 3mm | +18% SAC at 10m |
Regulator Drag | +4 BPM at 1.5kg+ force | +33% tank drain rate |
Water Temp (18°C) | +6 BPM | +2.7 L/min SAC |
Anxiety (Novice) | +10 BPM avg | 90% shorter dive time |
Test Error (±0.5 BPM) | — | ±9% time error at 30m |
Operational Insight:
During a 10m dive with SAC 15 L/min, a 1 BPM unmeasured increase from cold exposure means:
Air used/min: 15L × (Depth Factor 2.0) = 30 L/min → 33 L/min with extra breath
For a 3.0L/200 bar tank (usable 450L):
Planned time: 450L ÷ 30 L/min = 15 min
Actual time: 450L ÷ 33 L/min = 13.6 min
Result: 1.4-minute early air exhaustion—enough for missed safety stops.
Calibration Drill:
With tank at 200 bar, breathe normally for 300 seconds.
Record pressure drop: e.g., 194 bar → Δ6 bar.
SAC = (3.0L × 6 bar × 60) ÷ 300 sec = 3.6 L/min.
Verify against timed BPM: 10 breaths/60s = SAC 3.6 L/min ✓.
Discrepancies >7% indicate measurement error—repeat.
Step 3: Multiply Rate by Air per Breath (Tank Capacity ÷ Breaths)
Use your breathing rate (BPM) from Step 2 (e.g., 12.0 breaths/minute) and tank usable capacity from Step 1 (e.g., 3.0L tank × 150 bar reserve = 450 liters). Calculate air volume per breath:
Air per Breath (L) = Usable Capacity ÷ Total Breaths in Tank
First, determine total breaths: For 450L usable air and an average tidal volume of 1.5L/breath (healthy adult male), Total Breaths = 450L ÷ 1.5L = 300 breaths. Then:
Per-Breath Consumption = 450L ÷ 300 breaths = 1.5L/breath.
Critical correction: Actual tidal volume varies by ±23% due to physiology. Use your personalized data:
Attach a digital spirometer (120–250) to your regulator mouthpiece during surface testing.
Record 10 consecutive breaths: Typical outputs range from 1.2L/breath (relaxed) to 1.8L/breath (mild stress).
Calculate mean tidal volume (e.g., readings: 1.4, 1.6, 1.5, 1.3, 1.7L → avg = 1.5L).
Recompute per-breath air: If tidal volume = 1.5L, and BPM = 12.0, then:
Surface Air Consumption (SAC) = 1.5L/breath × 12 breaths/min = 18.0 L/min.
Pressure-to-volume conversion:
Tank pressure drop directly correlates to air used: 1 bar drop in a 3.0L tank = 3.0 liters consumed.
With SAC = 18.0 L/min, pressure decreases at 6.0 bar/minute (18 ÷ 3 = 6).
Validate: Time 60 seconds of breathing—pressure should fall from 200 bar to 194.0 bar (Δ = 6.0 bar ↔ 18.0L).
Environmental calibrations:
Factor | Adjustment to SAC | Data Source |
---|---|---|
Altitude (>300m) | +7%/1,000m | ISO 2533 air density tables |
Humidity (>80% RH) | +4% volume/breath | Gas law: Moist air = lower O₂ density |
Regulator flow rate | ±1.5L/min | Test with flowmeter at 1.0 bar cracking pressure |
Real-world error case:
If tidal volume isn’t measured (assuming 1.5L) but actual is 1.8L (+20% variation):
Actual SAC = 1.8L × 12 BPM = 21.6 L/min
Planned SAC error = 18.0 L/min (-16.7% underestimation)
At 30m depth (factor = 4.0):
Planned consumption: 18.0 × 4.0 = 72 L/min
Actual consumption: 21.6 × 4.0 = 86.4 L/min
For 450L usable air:
Planned bottom time: 450 ÷ 72 = 6.25 min
Actual bottom time: 450 ÷ 86.4 = 5.21 min → 1.04-minute deficit (safety violation risk)
Advanced verification protocol:
With tank at 200 bar, breathe normally for 5 minutes (300 seconds).
Record pressure drop: e.g., 200 → 191 bar (Δ9 bar).
Compute SAC: (3.0L × 9 bar × 60) ÷ 300 sec = 16.2 L/min.
Cross-check with BPM method:
Tidal volume = SAC ÷ BPM = 16.2 ÷ 12.0 = 1.35L/breath
Spirometer avg = 1.38L → ±2.2% error (acceptable).
Operational Thresholds:
SAC >25 L/min = Service regulator (valve friction > 1.8kg opening force)
SAC variance >15% between dives = Recheck gear/physiology
Step 4: Adjust for Water Depth
At sea level (1 ATM), a full breath contains ~1.2 grams of oxygen per liter in standard air (21% O₂). When descending, every 10 meters of saltwater increases ambient pressure by 1 ATM (1.03 kg/cm²), forcing your lungs to process densely packed molecules to fill alveoli. The depth multiplier formula [(Depth ÷ 10) + 1] precisely quantifies this density effect:
10m = (10 ÷ 10) + 1 = 2.0x air consumption
20m = (20 ÷ 10) + 1 = 3.0x
30m = (30 ÷ 10) + 1 = 4.0x
Using your Surface Air Consumption (SAC) rate from Step 3 (e.g., 18.0 L/min):
Actual Air Consumption (AAC) = SAC × Depth Factor
Diving to 18m: Factor = (18 ÷ 10) + 1 = 2.8 → AAC = 18.0 × 2.8 = 50.4 L/min
Calibrate for critical variables:
Variable | Adjustment | Data Source |
---|---|---|
Salt vs. Fresh Water | +1.2% factor per 10m | Buoyancy: Saltwater density = 1.025 g/cm³ vs. 1.000 g/cm³ |
Workload Intensity | +0.3–0.7x factor | Finning at 1.5 knots raises SAC by 40% |
Thermal Stress | +4%/°C below 20°C | 5°C water at 30m = 4.0 × 1.20 = 4.8x multiplier |
Tank Composition | Steel tanks: -0.05x | Hydrostatic compression reduces aluminum tank volume by 0.3% at 40m |
Pressure-based validation:
At surface: Record SAC via pressure drop: 3.0L tank × 6.0 bar/min = 18.0 L/min
At 18m: Time 60 seconds—pressure drops ~28 bar (since 50.4 L/min ÷ 3.0L volume = 16.8 bar/min × 1.67 min = 28 bar)
Verify: Expected AAC (50.4 L/min) ÷ Tank Volume (3.0L) = 16.8 bar/min
Extreme error case (ignoring depth factor):
Planned dive: 18m, SAC 18.0 L/min, no adjustment
Actual AAC required: 50.4 L/min
Usable air (from 3.0L/200 bar tank): 450L
Expected dive time: 450L ÷ 50.4 L/min = 8.93 min
Unadjusted plan assumes: 450L ÷ 18.0 L/min = 25.0 min
Result: 16.1-minute overestimation → Air exhaustion at ~9m during ascent
Real-world corrections table:
Depth | Formula Factor | Workload Adj. (Moderate) | Cold Adj. (10°C) | Final Multiplier |
---|---|---|---|---|
10m | 2.0 | +0.4 | +0.2 | 2.6x |
20m | 3.0 | +0.6 | +0.3 | 3.9x |
30m | 4.0 | +0.8 | +0.4 | 5.2x |
Operational :
Pre-dive: Compute base factor using exact planned max depth (in meters)
Add buffer: +0.5x if water <15°C, +0.7x if strong current (>1 knot)
Validate in-water: At target depth, time pressure drop for 30 seconds
If tank shows 8.4 bar loss in 0.5 min for 3.0L tank: AAC = (3.0L × 8.4 bar × 2) = 50.4 L/min → Matches plan
Abort thresholds: AAC exceeding 55 L/min in AL80 tanks (11.1L) mandates ascent → Triggers at 22m if SAC >25 L/min
Failure signature: Pressure dropping >15 bar/minute at 15m in a 3.0L tank indicates unmodeled workload/cold stress – immediately ascend 3 meters and recalculate.
Formula Limits:
Fails below 10m: Use absolute pressure (ATM) instead: Depth Factor = (Depth × 0.1) + 1
Irrelevant for trimix: Helium reduces density penalties → At 40m, 21/35 trimix = 3.1x vs. air’s 5.0x
Surface supply: Free-flow regs add +12% AAC independent of depth
Step 5: Estimate Dive Time
Subtract mandatory 50-bar reserve and account for ascent/safety stop consumption before bottom time math—for a 3.0L tank starting at 200 bar, start pressure (200 bar) – reserve pressure (50 bar) = 150 bar usable, converting to 450 litres (3.0L × 150 bar), but immediately subtract ascent allocation: Ascending from 30m at 9m/minute takes 3.3 minutes while consuming air at depth factor 3.0 (average during ascent), so if your Surface Air Consumption (SAC) is 15 L/min, ascent requires 15 L/min × 3.0 factor × 3.3 min = 148.5 litres, plus 3-minute safety stop at 5m (factor 1.5) consuming 15 × 1.5 × 3 = 67.5 litres, leaving only 450 – 148.5 – 67.5 = 234 litres for bottom time.
Apply depth-adjusted rate: If diving at 20m (factor 3.0) with SAC 15 L/min, actual consumption is 45 L/min (15 × 3.0). Bottom time calculation:
Available Bottom Time (min) = (Usable Air After Ascent Allocation) ÷ Adjusted Consumption Rate
= 234 litres ÷ 45 L/min = 5.2 minutes.
Pressure-gauge validation method:
Monitor real-time pressure drop during the dive: At 20m, if pressure falls from 200 to 180 bar in 5 minutes, consumption is (20 bar drop × 3.0L) ÷ 5 min = 12 L/min actual versus planned 45 L/min, indicating 73% lower burn rate—extending bottom time to 9.7 minutes.
Recompute every 5 minutes: If consumption spikes to 55 L/min (over 22% variance), abort at 100 bar to retain 50 bar reserve.
Error impact table:
Miscalculation | Depth | SAC | Time Error | Air Deficit |
---|---|---|---|---|
Ignored reserve | 20m | 15 L/min | +1.8 min | -81L at ascent start |
Omitted ascent allocation | 30m | 20 L/min | +2.4 min | -192L safety violation |
SAC underestimated by 3 L/min | 25m | Planned 18 L/min (Actual 21) | -1.1 min | -76L at 10m |
Depth error ±3m | Planned 18m (Actual 21m) | 15 L/min | -0.7 min | -47L reserve breach |
Worst-case contingency:
At 25m, SAC 22 L/min with 3.0L tank:
Planned: 45 L/min adjusted (22 × 2.5)
Usable air: 450 litres
Planned time: 10 min
Reality: Cold stress raises SAC to 28 L/min (+27%) → 70 L/min consumption
Actual bottom time: 450 ÷ 70 = 6.4 min
Deficit vs. plan: 3.6 minutes less air
Protocol: Trigger ascent at 120 bar (vs. planned 80 bar threshold)
Field Reference Cheat Sheet
Reserve pressure: 50 bar (all dives)
Ascent allocation: 40 litres per 10m ascended (e.g., 30m → 120 litres)
Safety stop: 67 litres (3 min @ 5m)
Check frequency: Every 5 minutes ±0.2 min timer error
Abort thresholds:
Pressure drop >15 bar/min in 3L tanks
Time variance >12% from plan
Depth >+3m from max planned
Calibration Dive Test Data
Depth | SAC (L/min) | Planned Time (min) | Actual Time (min) | Variance |
---|---|---|---|---|
10m | 18 | 12.5 | 11.8 | -5.6% |
20m | 24 | 6.2 | 5.9 | -4.8% |
30m | 33 | 4.1 | 3.7 | -9.8% |
Note: Always build in 15% buffer using worst-case actuals. |
Step 6: Check Pressure Regularly During the Dive
Verify pressure every 5 minutes ±0.3 seconds timer precision during stable depth phases, but immediately after any depth change exceeding 3 meters, perform a spot-check since transitioning from 30m to 15m drops consumption by 42% yet most divers misjudge flow rate reductions. Use 60-second pressure-trend analysis after depth shifts: If descending 8 meters in 45 seconds (rate 10.7 meters/minute), the pressure gauge should reflect 13–16 bar instantaneous drop in a 3.0L tank if your SAC rate is 20 L/min, because at new depth (28m), the 3.8x depth factor multiplies consumption to 76 L/min, consuming 1.27 litres/second or 4.23 bar/second loss in a 3.0L system—if readings deviate >±5%, signal your buddy to halt for recalibration.
Critical consumption thresholds: Always cross-reference gauge data against planned adjusted air consumption (AAC). At 20m depth with SAC 15 L/min, planned AAC is 45 L/min (15 × 3.0 factor), equating to pressure drop of 15 bar/minute (45 L/min ÷ 3.0L volume) so in 5 minutes, gauge should decline 75±3.8 bar accounting for current drag error; deviations >8% require immediate ascent at 9 meters/minute maximum velocity, since a 20% consumption spike in this scenario means actual AAC=54 L/min, draining reserve air 54% faster—breaching 50-bar margin before ascent initiation by 1.8 minutes.
Gauge reading technique: Hold the instrument <60 cm from your facemask to minimize parallax error, wait 3 seconds for needle/display stabilization (analog gauges drift ±1.5 bar in cold water), and note both current pressure and time elapsed since last check. Record digitally via waterproof slate: Initial reading 200 bar @ 14:00, second at 165 bar @ 14:05 → 35 bar drop in 5 min = 7 bar/min loss rate, validating against plan. Suspect regulator freeze if consumption jumps >30% during <10°C dives—a 50 L/min AAC surge at 30m expends 150 litres in 3 minutes, equal to 18% reserve air loss.
Contingency validation drill: Upon detecting >15% variance from planned AAC:
Signal buddy, halt activity, stabilize depth within ±1m
Time 60 seconds precisely with depth gauge
Note pressure start/end points: e.g., 120 bar → 112 bar
Calculate instant AAC: Δ8 bar × 3.0L = 24 litres consumed in 1 min = 1,440 L/hour rate
Compare to planned AAC: If exceeding plan ±20% tolerance, ascend immediately to ½ current depth
Systematic failure response: If pressure drops >2 bar per breath cycle (inhalation-exhalation) in 3.0L tanks, conduct positive pressure test: Blow forcefully through regulator—airflow resistance >0.5 kg/cm² indicates frozen valve, mandating air-sharing ascent at 9m/min max with ≥50% throttle on secondary regulator, since free-flow events drain 240–300 L/min in cold water (80–100 bar/min loss), exhausting 200-bar reserves in 1.5–2 minutes requiring emergency response time <30 seconds to initiate buddy breathing.
Minimum safety reserve: Always surface with ≥50 bar—equivalent to 150 litres in 3.0L tanks or 72 lungfuls at 2.08 litres/breath tidal volume
Critical alerts: Vibrate tank 3x if pressure <70 bar or consumption >20 bar/min
Gauge error margins: Analog instruments show ±4% variance at >40m, digital sensors ±1.2%
Thermal compensation: Pressure reads 4–7% lower in <10°C water than identical gas volume at surface
Air-sharing buffer: When buddy breathing, double consumption rate assumptions: AAC × 1.8 safety factor
Proven monitoring cadence:
Depths <18m: Checks every 300±5 seconds
Depths >18m: Checks every 180±3 seconds
Deco obligations: Checks every 90±1.5 seconds
Deadly latency example: Waiting 7 minutes to monitor at 30m:
Planned AAC: 60 L/min
Air consumed: 60 × 7 = 420 litres
In 3.0L tank: 420 ÷ 3.0 = 140 bar consumed
Starting pressure 200 bar → drops to 60 bar
Reserve margin breached: 10 bar below safety limit → Ascent compromised at 9m
Step 7: Check Results After Diving
Immediately post-surface, before removing gear, record four immutable datasets: actual bottom time from dive computer (e.g., 23 minutes 17 seconds), starting/ending tank pressures (e.g., 200 bar → 47 bar), depth profile peaks logged every 30 seconds (critical for weighted SAC calculations), and water temperature gradient measured at 5m intervals (e.g., surface 28°C, 20m 18°C, bottom 14°C). Convert pressure drop to volume consumed: (200 bar start – 47 bar end = 153 bar drop) × 3.0L tank = 459 litres used, but subtract 82 litres for ascent/safety stop (7 min ascent from 25m at 28 L/min average consumption) leaving 377 litres for bottom time versus planned 370 litres ±1.89% variance.
Recompute your actual SAC rate: Divide bottom time volume (377L) by mean depth factor-adjusted minutes—if you averaged 18m depth (factor 2.8) over 23.28 minutes, actual SAC = 377L ÷ (2.8 × 23.28 min) = 5.78 L/min, exposing a 14.2% error versus your pre-dive estimate of 5.0 L/min. Log this delta for gear diagnosis: A >15% positive discrepancy suggests regulator leak >1.5L/min at depth, while negative variance may confirm thermal compression benefits of new 5mm wetsuit.
Temperature-driven adjustments: Cold water (<12°C) inflates SAC rates by 0.4 L/min per 5°C drop due to metabolic load—if your 18m dive averaged 16°C versus practice dives at 26°C, add 0.8 L/min (10 × 0.08) to future cold-water SAC baselines. Saltwater density impacts require separate logging: At identical depths, 34 ppt salinity causes 3.7% higher consumption than freshwater quarries—a 12 L/min SAC dive in ocean environments becomes 12.44 L/min actual.
Statistical refinement over 3 dives:
Dive 1: Planned SAC 18.0 L/min, Actual 19.8 L/min (+10% error)
Dive 2: Planned 18.0 L/min, Actual 19.3 L/min (+7.2%)
Dive 3: Planned 18.0 L/min, Actual 19.1 L/min (+6.1%)
Compute mean variance (+7.77%) and standard deviation (±1.96%)—add permanent 7.8% buffer to all future SAC estimates to achieve ±0.5% accuracy. Identify outliers >2σ (Standard Deviation): A single dive showing +15.9% SAC variance triggers regulator flow test at 50m simulation pressure.
Gear failure signature analysis: Log hourly breathing apparatus performance—a consistent 3.2% SAC increase monthly correlates with second-stage orifice wear >400 dives, while spikes >28% indicate O-ring extrusion needing immediate replacement after 0.5 bar/minute leakage detection. Post-service benchmarks: After diaphragm replacement, SAC should drop 6.0% ±0.8 within three validation dives.
Long-term recalibration cycle: Every 25 dives or 18 months, rebaseline your breathing rate with spirometer-timed trials: Sit submerged in 26°C water for 10 minutes pre-stabilization, then measure 10 consecutive tidal volumes—discard highest/lowest readings and average the middle eight (median 1.4 litres/breath). Multiply by BPM rate (12.0) for corrected SAC (16.8 L/min), reducing cumulative prediction drift from 8.2% to <1.5% annually.
Critical Logging Metrics
Depth-time weighting: Calculate mean depth using depth readings × duration per segment summed ÷ total time
Ascent allocation formula: (Average depth (m) ÷ 3) × SAC (L/min) × 1.2 safety buffer
Gear impact coefficients:
New regulator: SAC reduction 7–11%
Worn fin straps: SAC increase 4–6%
Overweighted belt: SAC increase 1.2 L/min per 2kg excess
Error cascade thresholds: Abort dive planning if pre-dive SAC estimate exceeds last 3 dives’ mean by >9%
Proven recalibration frequency:
Novice divers (0–30 dives): Log adjustments every 1–2 dives
Intermediate (30–100 dives): Every 5 dives
Technical divers (100+ dives): Every 10 dives or depth >40m
Negligence consequence: Skipping logs for five consecutive 20m dives allows SAC drift to accumulate 18% error—on a 45-minute planned dive, actual air exhaustion occurs at 37 minutes, forcing omission of safety stop and incurring 15% DCS risk elevation.
Laisser un commentaire
Tous les commentaires sont modérés avant d'être publiés.
Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.